- Industrial Park Wastewater Treatment
- Coal Chemical Wastewater Treatment
- Wastewater Treatment From Photovoltaic Panel Slicing
- Petrochemical Energy Wastewater Treatment
- Dye And Pigment Wastewater Treatment
- Pesticide Wastewater Treatment
- River Water Quality Improvement
- Advanced Nitrogen And Phosphorus Removal
- Electroplating Wastewater Treatment
- Phthalic Anhydride Wastewater Treatment
- Liquor Brewing Wastewater Treatment
- Nuclear Industry Wastewater Treatment
- Electrolyzed Water Hydrogen Production Wastewater Treatment
- Seawater Desalination
- Bromine Resource Recovery
- Reverse Osmosis Brine Treatment
- Landfill Leachate Treatment
- Chemical Industry Wastewater Treatment
- Textile Printing And Dyeing Industry Wastewater Treatment
- Papermaking Industry Wastewater Treatment
- Livestock Farming Wastewater Treatment
- Water Treatment Systems For Hospitals, Hotels, Residences, And Public Spaces
- Wastewater Treatment Plant Wastewater Treatment
- Recycling Of Industrial Cooling Water
- Resource Extraction From Concentrated Brine In Seawater Desalination
- High-purity Water Production
Shanxi Jun'an Louw Dong Energy Technology Co., Ltd.

This project has a treatment capacity of 2,400 m3/d and is a wastewater treatment project for a key coal chemical enterprise located in the Wutong Industrial Park, Wutong Town, Xiaoyi City, Lvliang, Shanxi Province.
Longantai Company applies its self-developed oil separation and air flotation technology + LCO ozone catalytic oxidation technology + high-efficiency AO biochemical process. This combination effectively removes dozens of inorganic and organic compounds from the coal chemical wastewater. Inorganic compounds mainly include large amounts of ammonium salts, thiocyanates, sulfides, and cyanides; organic compounds include phenols, mono- and polycyclic aromatic compounds, and nitrogen, oxygen, and sulfur-containing heterocyclic compounds that are difficult to degrade.
The treatment ensures that the wastewater meets the "indirect discharge" parameters specified in Table 3 of GB16171-2012 "Pollutant Discharge Standards for Coking Chemical Industry," with the following standards: COD < 80 mg/L, ammonia nitrogen < 10 mg/L, and total nitrogen < 25 mg/L.
Wastewater Quality:
Design influent:
pH: 8-9.5
COD<sub>cr</sub>: 5,000-6,000 mg/L
NH<sub>3</sub>-N: 200-300 mg/L
Volatile phenols: 800-1,100 mg/L
Oil content: 100-250 mg/L
Sulfur compounds: 40-150 mg/L
Cyanides: 13-20 mg/L
Thiocyanates: 400-1,000 mg/L
The design effluent standards are:
COD: < 80 mg/L
Ammonia nitrogen: < 10 mg/L
Total nitrogen (TN): < 25 mg/L
Influent Water Volume: 2400 m3/d
Process Description: Raw water regulation tank + oil separation tank + air flotation unit + ozone pre-oxidation tank + AO biochemical process + ozone catalytic oxidation tank + BAF (biological aerated filter)

China